text/microsoft-resx
2.0
System.Resources.ResXResourceReader, System.Windows.Forms, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089
System.Resources.ResXResourceWriter, System.Windows.Forms, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089
Delete variable
rising vote
Falling Edge Alarm
Offset Number
Falling Edge
Communication Group
Data Type
Modify a variable
Bit Offset/Length
Rising Edge Alarm
New Variation
Alarm information Normal
Media type
Date and Time
Log information
Date and Time
Log Types
Date and Time
Operation information
Operation Type
The operation log
System Alarm
system log
PP
CP
Ca
PPK
CPK
Dev
Mean
SampleSize
Groups
Max
Min
Total
Average Value
Max
Min
Lower limit of specification
Upper limit of specification
Number of data groups
Sample Subgroup Size
target value
Negative 3x standard deviation
Standard deviation (within group)
Standard deviation (overall)
Positive 3x SD
CPL
CPU
CP
CPK
Ca
PPL
Ppk
PPU
PP
CpkGrade
Total number of samples
Ppm < LSL
Ppm Toatl
Ppm < USL
Clear data
Calculate CPK
Analytics options
Query
Generate dummy data
Magnitude
Stats
Process capability (within the group)
Other values
Calculated value
Measured performance
Process capability (overall)
Query options
Query time interval
XR Control Chart
CPK Analysis Chart
Sample run diagram
Mean Run Chart
Model
Material code
Start monitoring
Stop monitoring
chart1
chart1
Steel Shell Code
Cell Code Length
Cell Code Width
Test results of post-envelope alignment
Appearance test results after filming
Passage
Upload Status
The bottom height of GB code is from the cover plate
Details
Insulation film height from the bottom 1
Insulation film height from the bottom 2
Insulation film height from the bottom 3
Insulation film height from the bottom 4
Insulation film height from the bottom 5
Insulation film height from the bottom 6
Spray code
Intermediate diameter
Remarks
Comprehensive results
Cup size
Workstation
Time
Dust removal wind speed
Steel Shell Code
Passage
Upload result
Spray code
Remarks
Results
Cup size
Time
Passage
Tray code
Device Encoding
Material code
Remarks
Results
Time
Steel Shell Code
Passage
Remarks
Results
Time
Logging
Parameters
Structural parts tray
Cell incoming
Cell outbound
Parameter
Min
Max
Units
New Distribution Group
Delete Distribution Group
Modify Distribution Group
Whether feedback is required or not
whether to enable
Is it a triggered read
Distribution group name
ON
Whether feedback is required or not
Is it a triggered read
Length
Remarks
Start Address
Distribution Group Configuration
Distribution group name
Start Address
Length
Remarks
Export Excel
Time query
Export
Query
Export
Query
Export Excel
guide
Query
Query
guide
Query
shifts
Steel Shell Code
RFID
Statistics date
Statistics date
Statistics Time
Statistics Time
End time
Start Time
Barcode
End time
Start Time
Type
Historical production data query
Capacity statistics query
Log alarm data query
Statistics by Shift
Daily statistics
Statistics by week
Monthly statistics
Yiwei Power
Login
Yiwei Power
Start
49 Factory
Yiwei Power
Rolling equipment data acquisition system
Log Alarm
Data analysis
Data Monitoring
Data traceability
Centralized monitoring
Easy parameter setting
System Configuration
Managing Users
about
Show home screen
Exit
Hide Main Menu
Non-Swipe Mode
Smart Meter
UA
Total Power
Total Factor
Pt
Ct
Accumulated Power
UB
UC
IA
IB
IC
PowerA
PowerB
PowerC
Alarm Top10 Statistics
Capacity statistics
Bad item statistics
OK number
Superior Rate
Total Production
Utilization rate
Equipment No
Plant code
Line number
Model
Up time
Run time
Smart meter (device)
OK
Are you sure you want to exit the system?
Log out system
Cancel
Cancel
OK
Are you sure you want to exit the system?
Log out system
Delete model
Add model
Save the parameters
Parameter item name
Max
Min
Unit
Material code
Model
Remark
Current model
Model
Material code
THPR
Add PLC
Cancellation settings
Distribution Group Configuration
OK settings
Variable Configuration
Settings
rising vote
Heartbeat Address
IP Address
Active status
Heartbeat status
Modify a variable
PLC type
The port number
Remarks
Get MES parameters
Turn on swipe mode
PLC type configuration
Equipment No
Line number
Factory Code
Automatically switch the monitoring interface time
No operation automatically switches the monitoring interface
IP Address Method
Port number configuration
No operating automatic lock screen
Auto lock screen time
Number of welder power curve displays
Software automatically logs in
Automatically run KICOME when restarting my computer
Thread time-consuming log saving
MES/non-MES mode switching
Anemometer
debugging mode
Equipment alarm
Device parameter setpoint changed
Device parameter setpoint request
Equipment State
Employee Permissions Verification
Meter energy consumption
Raw material input information
Product inbound
Product outbound
Product Process Data
Product processing result data
PLC Configuration
MES Settings
MES parameter configuration
MES Configuration
PLC Configuration
System Configuration
127.0.0.1
9600
Add User
Empty message
Deleting a User
Modification User
Check/Uncheck all
Data analysis
Data traceability
Easy parameter setting
Log Alarm
System Configuration
Managing Users
Data analysis
Data traceability
user rights
Username
user password
IC Card No
Easy parameter setting
Log Alarm
System Configuration
Managing Users
IC Card No
Enter Password again
User Information
user rights
user password
User Information
Set Permission
User operation
Start Index
Variable address
Variable Name
Variable address
Variable Configuration
Distribution group name
Start Index
Bit Offset/Length
Variable Name
Remarks
Data Type
Linearity coefficient
Offset Number
MES is not logged in
PC write PLC time failed!
Add variable
Variable Configuration
Data Type
rising vote
Falling Edge Alarm
Length offset
Modify a variable
Remarks
Start Address
Variable address
Variable Name
Upper limit
Lower limit
Unsupported data type
Creates
Product model cannot be empty!
Superior Rate
Info
Modify
Full Day
Outbound
Failed creating temporary file
Delete it
Delete succeeded
Power value
Features to be developed!
Poor alignment test results after wrapping
Alignment test results after wrapping unknown
Figure 19 Historical alarm
Historical data
Variables
Variable name cannot be empty
The variable name already exists
Incorrectly formatted variable address
Each defective item
Start monitoring
Start monitoring failed
Incorrect address format, should start with 'D' followed by a number
The address format is incorrect, it should be a pure number
The address range exceeds the limit, and the end address cannot exceed 32767
型号选择
OPS Night Shift
Export report failed
Export report succeeded, do you want to open it now?
Export alarm succeeded, do you want to open it now?
The start time can not be greater than the end time
Currently in MES mode, please log in!
There are currently no alarms
You are not currently logged in, please log in!
Insufficient privileges for current logged in user!
Success
Open report record
Open alarm log
Inputs
Call the police TOP10
Alarm item
The operation log
Value
Data analysis
Data Report Export
New Variable
New variable created successfully
Invalid group name
Invalid start address
Time
Monday
Wednesday
Tuesday
Friday
Saturday
Thursday
Sunday
Do you want to save the modified configuration?
Are you sure you want to exit the system
please sign in here
No data found, please test
Permission Denied
Query time cannot exceed 7 days
Query range cannot exceed 1 day
Times
No address space available
No group names available, please add groups in Group.xlsx first
Not enough address space found
Material code cannot be empty!
Code error
log in system
Day Shift
Confirmation
system log
Remarks
Good products
Failed to get parameters
Please sign in with your card first!
Poor appearance test results after filming
Appearance test results after filming unknown
Start address format is incorrect
InBound
InBound failed
OutBound failed
Connect PLC
Connect PLC
Failed to connect to PLC, please check PLC connection configuration, network
Log out system
Communication Group
<strong>%s</strong> config saved successfully
Error
Length must be greater than 0
Length must be a number greater than 0
An error occurred while validating the configuration, please check if the input is correct
Verification Error
Default Group
Steel Shell Code
Cell Code Length
Cell Code Width
Test results of post-envelope alignment
Appearance test results after filming
Passage
Upload Status
The bottom height of GB code is from the cover plate
Details
Insulation film height from the bottom 1
Insulation film height from the bottom 2
Insulation film height from the bottom 3
Insulation film height from the bottom 4
Insulation film height from the bottom 5
Insulation film height from the bottom 6
Spray code
Intermediate diameter
Remarks
Comprehensive results
Cup size
Workstation
Time
Dust removal wind speed
AlarmTime
PLCAdress
AlarmContent
AlarmCount
Class
Day
ProdIn
ProdOut
Average Ppm
Average Operating Rate
Optimum Rate
Week
Total ProdIn
Total ProdOut
Average Ppm
Average Operating Rate
Production Yield Rate
Month
Total ProdIn
Total ProdOut
Average Ppm
Average Operating Rate
Production Yield Rate
TestTime
ProdIn
ProdOut
Average Ppm
Average Operating Rate
Production Yield Rate
Re-upload
Call the police for inquiry
User query failed
Error prompt
Query failed:
PC writes PLC time exception
Form loading exception
Chart initialization exception
Timed refresh exception
Updated 12-hour data anomalies
Update Efficiency Control Exception
Update Time Display Unexpected
Update energy display anomalies
Update Alarm Chart Anomalies
Update Bad Chart Anomalies
Quit Successfully
Quit the user
Stop connecting to PLC
Modify the automatic login method of the software
Modify the automatic startup method of the software
Modify the unoperational automatic screen locking method
Modify the lock screen interval
Modify the mode of automatic switching monitoring interface without operation
Modify the debugging mode
Modify the interval between switch monitoring interfaces
Modify the number of curve displays
Modify Swipe Mode
Currently logged in
Toggle Swipe Mode
Switching swiping mode successfully
Current user logged out
Prompt
Stop running before switching MES
Modify MES/non-MES mode switching
Successfully turning off mes mode
MES user logged out
Modify to get MES parameters
Modify thread time-consuming log saving
Start loading configuration parameters...
The configuration file is loaded
No PLC configuration information
Please check the profile
Failed to connect PLC
Successfully connect PLC
Anomalies occurred when connecting to PLC
Disconnected from PLC
Triggered the manual HMI pop-up window function
Failure of equipment
Equipment transformation
Engineering changes
MES downtime
Unusual quality
Accessories, material replacement
Poor incoming materials
To be expected
Quality inspection
Cleaning point inspection
The environment is not satisfied
Other unplanned downtime
HMI manual pop-up status has been uploaded successfully, code
D40 has been reset 0
The end state of the HMI manual pop-up window has been uploaded successfully, and the code
Inbound A station is sent to PLC
Inbound B station is sent to PLC
Inbound C station is sent to PLC
The total time taken to enter the station
Outbound A station is sent to PLC
Outbound B station is sent to PLC
Outbound C station is sent to PLC
Cell outbound A consumes a total time
Cell outbound B consumes a total time
Cell outbound C consumes a total time
Result data upload failed
MES parameter setting successfully
Start monitoring
Start to start monitoring failed
Stop connecting to PLC
Inbound workstation A paid mark is 0
Inbound workstation B paid mark is 0
Outbound workstation A paid mark is 0
Outbound workstation B paid mark is 0
Inkjet workstation A material sign is 0
Inkjet workstation B material sign is 0
Channel number