using System;
|
|
using System.Collections.Generic;
|
|
using System.Linq;
|
|
using System.Text;
|
|
using System.Threading.Tasks;
|
|
using JinYuan.Helper;
|
|
using JinYuan.Models;
|
|
using JinYuan.VirtualDataLibrary;
|
|
using PLCCommunication.Common;
|
|
using PLCCommunication.Common.DataConvert;
|
|
|
|
namespace JinYuan.ControlCenters
|
|
{
|
|
public partial class ControlCenter
|
|
{
|
|
public static string GetValueFromByteArray(byte[] bArray, string PLCGroupVariablekey, int offset = 0, Group pf = null)
|
|
{
|
|
return GetValueFromByteArray(bArray, getPLCVariable(PLCGroupVariablekey), offset, pf);
|
|
}
|
|
|
|
public static PLCGroupVariable getPLCVariable(string key)
|
|
{
|
|
PLCGroupVariable pLCGroupVariable = new PLCGroupVariable();
|
|
CommonMethods.PLCVariable.TryGetValue(key, out pLCGroupVariable);
|
|
return pLCGroupVariable;
|
|
}
|
|
|
|
/// <summary>
|
|
/// 获取MES返回结果
|
|
/// </summary>
|
|
/// <param name="bArray"></param>
|
|
/// <param name="var"></param>
|
|
/// <param name="offset"></param>
|
|
/// <param name="pf"></param>
|
|
/// <returns></returns>
|
|
public static string GetValueFromByteArray(byte[] bArray, PLCGroupVariable var, int offset = 0, Group pf = null)
|
|
{
|
|
string value = "0";
|
|
try
|
|
{
|
|
switch (var.DataType)
|
|
{
|
|
case "Float":
|
|
value = FloatLib.GetFloatFromByteArray(bArray, var.ArrayStart * 2 + offset, DataFormat.CDAB).ToString("0.###");
|
|
break;
|
|
case "Short":
|
|
value = ShortLib.GetShortFromByteArray(bArray, var.ArrayStart * 2 + offset).ToString();
|
|
break;
|
|
case "Int":
|
|
value = IntLib.GetIntFromByteArray(bArray, var.ArrayStart * 2 + offset).ToString();
|
|
break;
|
|
}
|
|
}
|
|
catch (Exception ex)
|
|
{
|
|
LogHelper.Instance.WriteError($"数据解析异常, 原因: {ex}", "SysErrorLog");
|
|
}
|
|
return value;
|
|
}
|
|
}
|
|
}
|